Furnace Service and Repair LAFAYETTE CO
If your heating system in Lafayette, CO is not working it is likely your furnace needs repair or a good servicing. At times the fix is simple, at times not. Our heating service technicians have years of experience working on furnaces like yours in Lafayette, CO. service vehicles are on call 24 hours per day are fully equipped with the tools and parts necessary to get your furnace back up and operating.
Our furnace repair, furnace service or replacement pricing is competitive. Our estimates are always firm with no hidden surprises. You can rely on to advise you properly and to do excellent work promptly.
| Furnace Service and Repair no heat. flue leaking water on to gas valve. gas valve rusted and dropping out. heat exhcnager heavy rust. blower motor bearings shot. recommend replace furnace. | EXCALIBUR, LAFAYETTE, CO |
| Furnace Service and Repair Gas furance blwoing cold air. limit switch failed at high temperature. checked gas pressure. pressure set at 4.3 wien it should have been 3.2. adjusted down & temperatures are within range. 2 yrs parts and labor warranty | SHOSHONE, LAFAYETTE, CO |
| Furnace Service and Repair Rudd mod # vaka060jaz ser # 5721f499708978 comp 28.9 fan 2.0 min fuse 50 amp others replaced contactor with too light duty contactor and did poor wire connection on incoming 240 vac side one side on conatctor has points weldeed together condenser fan running at low rpm on only one fuse one leg of 220 vac circuit cutler hammer c25bnb22ot 20 amp fla 30 amp resistive condenser fan and capacitor should be replaced | FALCON, LAFAYETTE, CO |
| Furnace Service and Repair Found yellow wire off of the y terminal to variable speed blower by zoning contractor gave cost & options to install standard motor | ELK TRAIL, LAFAYETTE, CO |
| Furnace Service and Repair Furnace repair | Indian Peak Rd., LAFAYETTE, CO |
| Furnace Service and Repair Furnace check. will recommend to service furnace and clean. furnace is working properly at this time. cleaned and service furnace is working properly at this time | WINDROW, LAFAYETTE, CO |
| Furnace Service and Repair Furnace not coming on blowing cold air. found circuit board bad. replaced with universal circuit board. once inside the furnace found limit was also bad. replaced for no charge at same time 2 yrs parts and labor warranty. | MILO CIRCLE, LAFAYETTE, CO |
| Furnace Service and Repair Pressure limit switch was wrong. temp replaced found 4 ton blower on that was a used furnace and duct work is too small. have used furnace installed it is too large for duct work. | MILO CIRCLE, LAFAYETTE, CO |
| Furnace Service and Repair No heat. furnace short cycling. found pressure switch not making removed and cleaned out tubes. all working at this time. reprogrammed thermostat to be 68deg all the time except if customer overrrides the settings. | E EMMA ST, LAFAYETTE, CO |
| Furnace Service and Repair Furance blowing cold air. limit switch failed at high temperature. checked gas pressure. pressure set at 4.3 wien it should have been 3.2. adjusted down & temperatures are within range. 2 yrs parts and labor warranty | SHOSHONE, LAFAYETTE, CO |
| Furnace Service and Repair No heat. flue leaking water on to gas valve on furnace. gas valve rusted and dropping out. heat exchanger heavy rust. blower motor bearings shot. recommend replace furnace. | EXCALIBUR, LAFAYETTE, CO |
| Furnace Service and Repair Lafayette removed existing 2 pvc venting and installed new 3 pvc venting system. old vent was too small for furnace size and number of 90s used. also performed a pro tune and clean furnace. cycled furnace numerous times and ran furnace and observed operation until thermostst cycled. | SHOSHONE, LAFAYETTE, CO |
| Furnace Service and Repair Removed existing 2 pvc venting and installed new 3 pvc venting system. old vent was to small for furnace size and number of 90s used. also performed a pro tune and clean furnace. cycled furnace numerous times and ran furnace and observed operation until thermostst cycled. | SHOSHONE, LAFAYETTE, CO |
| Furnace Service and Repair No heat carrier 90% furnace. had to rerun exhaust and combustion with a pro tune and clean furnace. carrier 90% furnace has ran w/2 pvc. furnace was going out on pressure switch failure. found water in inducer motor drain and cleaned. flu was termanaded in front of ac unit outside could be | SHOSHONE, LAFAYETTE, CO |
| Furnace Service and Repair Removed existing 2 pvc venting and installed new 3 pvc venting system. old vent was to small for furnace size and number of 90s used. also performed a pro tune and clean furnace. cycled furnace numerous times and ran furnace and observed operation until thermostst cycled. | SHOSHONE, LAFAYETTE, CO |
| Furnace Service and Repair No heat carrier 90% furnace. had to rerun exhaust and combustion with a pro tune and clean furnace. carrier 90% furnace has ran w/2 pvc. furnace was going out on pressure switch failure. found water in inducer motor drain and cleaned. flu was termanaded in front of ac unit outside could be | SHOSHONE, LAFAYETTE, CO |
| Furnace Service and Repair Removed existing 2 pvc venting and installed new 3 pvc venting system. old vent was to small for furnace size and number of 90s used. also performed a pro tune and clean furnace. cycled furnace numerous times and ran furnace and observed operation until thermostst cycled. | SHOSHONE, LAFAYETTE, CO |
| Furnace Service and Repair No heat carrier 90% furnace. had to rerun exhaust and combustion with a pro tune and clean furnace. carrier 90% furnace has ran w/2 pvc. furnace was going out on pressure switch failure. found water in inducer motor drain and cleaned. flu was termanaded in front of ac unit outside could be | SHOSHONE, LAFAYETTE, CO |
| Furnace Service and Repair No heat. found dirty flame sensor clean flame sensor | SAGRIMORE, LAFAYETTE, CO |
| Furnace Service and Repair Furnace not wking properly found dirty unit. will give cost and options cleaned furnace and unit is wking properly at this time. | STARLINE, LAFAYETTE, CO |