is one of the leading providers of air conditioner repair, and air conditioning service in Denver, CO, offering timely solutions to problems related to air conditioners. Our HVAC technician will come to your rescue when you want emergency air conditioning repair, or just need a hand with your residential or commercial cooling problems.
You’ll find we take our job seriously and highly value the trust that is placed in us. goes far beyond what others do by investing in the training and equipment necessary to protect your home or family in Denver, CO properly.
| Air Conditioning Service and Repair Condensor kept shutting down, was very dirty. replace & clean unit also replace condensor fan motor. then checked compressor. | NIAGARA ST, DENVER, CO |
| Air Conditioning Service and Repair Repaired coil as per bid. a/c is working properly at this time. | E BATES DR, DENVER, CO |
| Air Conditioning Service and Repair Check a/c system. found oil covering condensing coil | S QUEBEC, DENVER, CO |
| Air Conditioning Service and Repair A/c not cooling very well. recommened a proton clean, found a/c indoor coil very dirty and cleaned the indoor coil. | SHERMAN, DENVER, CO |
| Air Conditioning Service and Repair a/c unit not working. found breaker tripped turned back on dead short to ground | EAST 39th, DENVER, CO |
| Air Conditioning Service and Repair Swamp cooler not working properly, will need to replace belts. installed new belts and adjust motor tension, also made distribution tube adjustment and cleaning | PECOS ST, DENVER, CO |
| Air Conditioning Service and Repair Service rooftop units change filters on all 3 units for north end of building complete check of operation ok on all units at this time | E 51ST AVE, DENVER, CO |
| Air Conditioning Service and Repair A/c not working. protune and clean blower motor | SHERMAN, DENVER, CO |
| Air Conditioning Service and Repair Air conditioner not working. condensor kept shutting down, was very dirty. replace & clean unit also replace condensor fan motor. then checked compressor. gave cost & opt. | NIAGARA ST, DENVER, CO |
| Air Conditioning Service and Repair Air conditioning not working. repaired coil as per bid. a/c is working properly at this time. | E BATES DR, DENVER, CO |
| Air Conditioning Service and Repair A/c not working. check a/c system. found oil covering condensing coil will give opt. to replace. | S QUEBEC, DENVER, CO |
| Air Conditioning Service and Repair A/c not working. checked a/c compressor its not running. attempted to contact owner not successful also waited 20 mins later, than spoke w/owner no work was approved at this time. | E, DENVER, CO |
| Air Conditioning Service and Repair swamp cooler install on roof 62x62x62 3 hp motor bill will include hook up disassemble of old unit crane service and all other work | PECOS ST, DENVER, CO |
| Air Conditioning Service and Repair a/c not cooling very well. recommened a pro tune clean, found a/c indoor coil very dirty and cleaned the indoor coil. | SHERMAN, DENVER, CO |
| Air Conditioning Service and Repair a/c unit not working. found breaker tripped turned back on dead short to ground | EAST 39th, DENVER, CO |
| Air Conditioning Service and Repair A/c not cooling. bad compressor replaced working at this time | EAST 39th, DENVER, CO |
| Air Conditioning Service and Repair Furnace not blowing air. check furnace. customer request cost for new air condition unit & 40 gallon water heater | QUITMANS, DENVER, CO |
| Air Conditioning Service and Repair Replace heat exchanger, clean evap coil and install filter door and explained how to change filters. | E, DENVER, CO |
| Air Conditioning Service and Repair Installed shut-off valve to water that supply to swamp cooler. | FEDERAL, DENVER, CO |
| Air Conditioning Service and Repair a/c not keeping up on 1st floor - will return to install new a/c unit thurs. | SO. HIGH, DENVER, CO |
| Air Conditioning Service and Repair Checked a/c making noise silver tape on blower door causing a humming sound. checked also a water spotting sometime on basement floor. determined to be main 1/2 bath toilet seal, pulled re-seal and re-set toilet. 2yrs warr .- double wax as flange not above tile floor | S HUDSON, DENVER, CO |
| Air Conditioning Service and Repair Returned to install new a/c unit onto main floor. from invoice #40675 adapted furnace & duct work to fit a/c coil. new line set and condensor, also installed new thermostat upstairs. condensate pump also to drain furnace. | SO. HIGH, DENVER, CO |
| Air Conditioning Service and Repair Air condition unit not cooling. found unit dirty and not coming on. cleaned unit and turned breaker back on. unit working properly at this time. | HOOKER, DENVER, CO |
| Air Conditioning Service and Repair Swamp cooler not cooling. checked cooler - needs replaced- gave cost and options for air condition unit | POPLAR ST, DENVER, CO |
| Air Conditioning Service and Repair Swamp cooler not acting properly- found problem due to heat gain in house- installed customer supplied fill valve and flapper | ALBION, DENVER, CO |
| Air Conditioning Service and Repair Furnace and air condition unit not working. found transformer bad janitrol. replace transformer units working at this time. | EAGLE ST, DENVER, CO |
| Air Conditioning Service and Repair No air condition found unit wires cut to fan motor due to age will recommend to replace fixed wires and air condition unitworking at this | MELODY, DENVER, CO |
| Air Conditioning Service and Repair Checked on cooling in office area- discussed with customer decided to do new pads in two south coolers new urninal mens restroom with auto flush valve rebuild womens toilet tank | E 51ST AVE, DENVER, CO |
| Air Conditioning Service and Repair Started only two south of 4 coolers in office area with new pads floats and drains- replaced fill control handle and flapper in womens restroom- picked up full flush urinal with auto flush valve installed in mens restroom | E 51ST AVE, DENVER, CO |
| Air Conditioning Service and Repair While starting swamp cooler found pads and pump destroyed by possible bird- installed new pads swamp cooler took 16 pads- also installed new pump | PECOS ST, DENVER, CO |
| Air Conditioning Service and Repair Started evap cooler prepaid winterization, cleaned floor drain, located picked up and installed new kitchen sink to existing faucet and disposal- 5 yr warranty on sink 1 yr on drain clear | E JEWELL, DENVER, CO |
| Air Conditioning Service and Repair No air condition found unit wires cut to fan motor due to age will recommend to replace fixed wires and air condition unitworking at this | MELODY, DENVER, CO |
| Air Conditioning Service and Repair Checked on cooling in office area- discussed with customer decided to do new pads in two south coolers new urninal mens restroom with auto flush valve rebuild womens toilet tank | E 51ST AVE, DENVER, CO |
| Air Conditioning Service and Repair Started only two south of 4 coolers in office area with new pads floats and drains- replaced fill control handle and flapper in womens restroom- picked up full flush urinal with auto flush valve installed in mens restroom | E 51ST AVE, DENVER, CO |
| Air Conditioning Service and Repair While starting swamp cooler found pads and pump destroyed by possible bird- installed new pads swamp cooler took 16 pads- also installed new pump | PECOS ST, DENVER, CO |
| Air Conditioning Service and Repair Started evap cooler prepaid winterization, cleaned floor drain, located picked up and installed new kitchen sink to existing faucet and disposal- 5 yr warranty on sink 1 yr on drain clear | E JEWELL, DENVER, CO |
| Air Conditioning Service and Repair Start up to 2 swamp cooler- new drain on upper cooler- prepaid winterize both coolers | S NIAGARA, DENVER, CO |
| Air Conditioning Service and Repair Start up swamp cooler- started swamp cooler checked system- found system working properly- did not prepay for shutdown | SHANGRI LA, DENVER, CO |
| Air Conditioning Service and Repair Startup swamp cooler- cleaned pan oil bearings- checked water lines for any leaks- pads ok at this time- may need to replace next year- arctic circle- apo56279 m#sd630g s#a05000160- prepaid for winterization | MILWAUKEE, DENVER, CO |
| Air Conditioning Service and Repair Checked evapcooler in kitchen area- pump failed needs replaced- located picked up installed new pump on evapcooler- 2 year warranty | S NIAGARA, DENVER, CO |
| Air Conditioning Service and Repair Roof access- put pump in water- recommened to replace with new swamp cooler | KALAMATH, DENVER, CO |
| Air Conditioning Service and Repair Air condition not turning on- found motor not starting but will run if spun manually- when unit comes on fan motor is spinning backwards- replaced capacitor and rewired blower motor- all working at this time, if quits again will need to replace motor- also washed dirt out of unit and coil- installed new air condition blower motor 2 years parts/labor | E 120TH PL, DENVER, CO |
| Air Conditioning Service and Repair Checked air condition- low on freon- oil and dirt at section king valve- replaced valve and charged system | XAVIER ST, DENVER, CO |
| Air Conditioning Service and Repair Air condition making noise downstairs- fan is out of balance due to dirt- will need to clean air condition and gas furnace motor- also recommended cutting filter door in for easy access and ductwork cleaning. performed clean on air condition unit and gas furnace. | S. DAYTON, DENVER, CO |
| Air Conditioning Service and Repair Air condition not cooling found 2 air conditioning units- one froze up and the other not pumping freon- basement air conditioning unit not installed properly and burnt up- possibly due to improper installation and wrong size piping recommend installing new proper size air conditioning unit with all new piping routed through basement no attic- also main floor air condition piping goes through attic and installed on old coil | KALAMATH, DENVER, CO |
| Air Conditioning Service and Repair Air condition not working- found bad condenser motor-installed new motor and unit working properly at this time. | S CHERRY, DENVER, CO |
| Air Conditioning Service and Repair Start up to 2 swamp cooler- new drain on upper cooler- prepaid winterize both coolers | S NIAGARA, DENVER, CO |
| Air Conditioning Service and Repair Start up swamp cooler- started swamp cooler checked system- found system working properly- did not prepay for shutdown | SHANGRI LA, DENVER, CO |
| Air Conditioning Service and Repair Startup swamp cooler- cleaned pan oil bearings- checked water lines for any leaks- pads ok at this time- may need to replace next year- arctic circle- apo56279 m#sd630g s#a05000160- prepaid for winterization | MILWAUKEE, DENVER, CO |
| Air Conditioning Service and Repair Found a/c not working - breaker was tripped - turned breaker back on and advise them to they needed to pro tune & clean unit & change filters as recommended as before | E 2ND AVE, DENVER, CO |
| Air Conditioning Service and Repair a/c leaking & drain. found system dirty. cleaned complete system - checked charge & everything working. fixed leaking fitting & installed new shutoff for humidifier. all working & no leaks. cleaned shower head in downstairs bathroom. gave price for a service partner plan | ZUNI ST, DENVER, CO |
| Air Conditioning Service and Repair Pulled blower motor & cleaned. clean evap coil & cleaned condensor coil. checked super heat. | CYD DR., DENVER, CO |
| Air Conditioning Service and Repair a/c not working, found bad condensing fan motor, will give cost to replace. installed a new condenser fan motor. | E 40TH PL, DENVER, CO |
| Air Conditioning Service and Repair A/c not working on the east side. found breaker tripped in electrical panel. 50amp - unit drawing 25 amps. all running at this time. recommend complete cleaning of a/c & replace filters in air handler. | E 2ND AVE, DENVER, CO |
| Air Conditioning Service and Repair coil damage by hail. gave cost & options to repair or replace options to repair a/c. combing coil potentially will not completely fix coil. possibly that coil will always be damaged without replacing coil. if coil is combed it will not be as good as normal conditions. customer needs to submit bid to insurance. m/n rcc30a2b. | E BATES DR, DENVER, CO |
| Air Conditioning Service and Repair A/c leak search, will attempt to find leak in system. charged system and it is working at this time. | SOUTH, DENVER, CO |
| Air Conditioning Service and Repair A/c not working, found a/c system overcharged and empty of freon, will give cost & options. | SOUTH, DENVER, CO |
| Air Conditioning Service and Repair Limit open all 3 resetable limits on burner box bypassed and disconnected breaker on off blower burners a coil very dirty inducer ...cleaned a coil blower burners | W 9TH AVE, DENVER, CO |
| Air Conditioning Service and Repair No air condition found unit wires cut to fan motor due to age will recommend to replace fixed wires and air condition unitworking at this | MELODY, DENVER, CO |
| Air Conditioning Service and Repair Checked on cooling in office area- discussed with customer decided to do new pads in two south coolers new urninal mens restroom with auto flush valve rebuild womens toilet tank | E 51ST AVE, DENVER, CO |
| Air Conditioning Service and Repair Started only two south of 4 coolers in office area with new pads floats and drains- replaced fill control handle and flapper in womens restroom- picked up full flush urinal with auto flush valve installed in mens restroom | E 51ST AVE, DENVER, CO |
| Air Conditioning Service and Repair While starting swamp cooler found pads and pump destroyed by possible bird- installed new pads swamp cooler took 16 pads- also installed new pump | PECOS ST, DENVER, CO |
| Air Conditioning Service and Repair Started evap cooler prepaid winterization, cleaned floor drain, located picked up and installed new kitchen sink to existing faucet and disposal- 5 yr warranty on sink 1 yr on drain clear | E JEWELL, DENVER, CO |
| Air Conditioning Service and Repair Swamp cooler not cooling. checked cooler - needs replaced- gave cost and options for air condition unit | POPLAR ST, DENVER, CO |
| Air Conditioning Service and Repair Swamp cooler not acting properly- found problem due to heat gain in house- installed customer supplied fill valve and flapper | ALBION, DENVER, CO |
| Air Conditioning Service and Repair Resecured panel to swamp cooler | PECOS ST, DENVER, CO |
| Air Conditioning Service and Repair Installed hard start kit, found compressor not turning on and a/c is working at this time | IRVING, DENVER, CO |
| Air Conditioning Service and Repair A/c not working. found very dirty unit recommend a/c service and clean. | CLERMONT, DENVER, CO |
| Air Conditioning Service and Repair A/c not blowing air. found blower motor bad. replaced motor and unit working properly at this time. | EAST 39th, DENVER, CO |
| Air Conditioning Service and Repair No air condition found unit wires cut to fan motor due to age will recommend to replace fixed wires and air condition unitworking at this | MELODY, DENVER, CO |
| Air Conditioning Service and Repair Checked on cooling in office area- discussed with customer decided to do new pads in two south coolers new urninal mens restroom with auto flush valve rebuild womens toilet tank | E 51ST AVE, DENVER, CO |
| Air Conditioning Service and Repair Started only two south of 4 coolers in office area with new pads floats and drains- replaced fill control handle and flapper in womens restroom- picked up full flush urinal with auto flush valve installed in mens restroom | E 51ST AVE, DENVER, CO |
| Air Conditioning Service and Repair While starting swamp cooler found pads and pump destroyed by possible bird- installed new pads swamp cooler took 16 pads- also installed new pump | PECOS ST, DENVER, CO |
| Air Conditioning Service and Repair Started evap cooler prepaid winterization, cleaned floor drain, located picked up and installed new kitchen sink to existing faucet and disposal- 5 yr warranty on sink 1 yr on drain clear | E JEWELL, DENVER, CO |
| Air Conditioning Service and Repair Free estimate sprinkler installation, air conditioning diagnostic, repair - irrigation | W. 32nd Ave. (check in), Denver, Co |
| Air Conditioning Service and Repair Both a/c would not cool had freon leaks on both units recharged freon low pressure high pressure air testwith nitrogen repaired leaks at evap coils replaced valve corre and fixed leaks at service valves recharged units | KEARNEY ST, DENVER, CO |
| Air Conditioning Service and Repair Start up cooler replaced wtaer line in attic move swamp cooler control | S POPLAR, DENVER, CO |
| Air Conditioning Service and Repair Finihing up installation of swamp cooler | GLENCOE ST, DENVER, CO |
| Air Conditioning Service and Repair Protune and clean air condition unit condenser dirty a coil needs to be checked low on r410a | COOK ST, DENVER, CO |
| Air Conditioning Service and Repair No cool 57' wbr 77 dbr 49'sa 28' drop filter 70% plugged condenser dirty a coil needs to be checked undercharged not guaranteed as a coil could be dirty | CENTRAL, DENVER, CO |
| Air Conditioning Service and Repair Minor clean of air condition unit | ELDER CIR, DENVER, CO |
| Air Conditioning Service and Repair Swamp cooler start up remove and fold cover connect valve and check float and pump dist tubes and oil motor | RUTH WAY, DENVER, CO |
| Air Conditioning Service and Repair Tstat will not run a/c condenser runs constantly stat needs to be rewired slightly 77 ambient 50'sl 75ra 52'sa 23' drop | E., DENVER, CO |
| Air Conditioning Service and Repair Replace blower motor | S, DENVER, CO |
| Air Conditioning Service and Repair Pro tune and clean cleaned indoor coil and cleaned indoor blower motor and blower cleaned outdoor unit with a=water add freon to proper level supply heat 6' outdoor temp 82 20 temp differential call in september | W 38TH AVE, DENVER, CO |
| Air Conditioning Service and Repair Installed new 2 ton 13 seer r22 condenser included a txv valve leveled concrete pad checked all refrigerant levels everything working well at this time mod # gsc130241 ser # 0909080357 | E, DENVER, CO |
| Air Conditioning Service and Repair Service agreement protune and clean and 30 amp contactor replacement found burned up and capacitor was not hooked up yo contactor which wasn't allowing compressor to come on | CHERRY, DENVER, CO |
| Air Conditioning Service and Repair A/c not working properly. checked elctrical breaker was turned off | S DUDLEY, DENVER, CO |
| Air Conditioning Service and Repair Checked hvac unit found no filters in return air unit very dirty recommend complete cleaning and service | S COLO BLVD, DENVER, CO |
| Air Conditioning Service and Repair Replaced 30 amp fuse in disconnect condenser is very dirty and cleaning is recommended also unit is undercharged | ZUNI ST, DENVER, CO |
| Air Conditioning Service and Repair A/c check customer needed verification that unit a/c fan coil system was working unit working fans came on and are producing a 15' temp diff across coil units are working ok and are producing cool air building chiler operating and is working good | ALBION ST, DENVER, CO |
| Air Conditioning Service and Repair Repair condensate line condensate drain on a/c coil was stopped backwards recommend cutting pvc shorter to create slope so it will drain also recommend cleaning condenser | HUMBOLDT, DENVER, CO |
| Air Conditioning Service and Repair A/c not working found a thermostat wire to condenser not connected to the computer possible other problems | E FLORIDA, DENVER, CO |
| Air Conditioning Service and Repair Checked window unit low on charge recommended new as to cost to repair or recharge unit- cust chose new unit installed new window a/c in living room i (tom) damaged unit in bedroom looked at charged & repaired as needed & recharged all ok at this time 2yr on unit in bedroom from todays date 6/24/08 | EAST, DENVER, CO |
| Air Conditioning Service and Repair Removed cooler & properly raised duct work & reset cooler. customer supplied new motor and float - needs grill inside. | CLAY ST #13, DENVER, CO |
| Air Conditioning Service and Repair Swamp cooler not working over secretary desk | E 51ST AVE, DENVER, CO |
| Air Conditioning Service and Repair No air on upstairs floor found ductwork not properly sealed found several leaks found all the upstairs registers pipe with 4 round pipe at the plentium/ recommended to increase supply & seal duct work | CENTRAL, DENVER, CO |
| Air Conditioning Service and Repair Swamp cooler not cooling found pan with no water float is all the way down- made adjustment on float | E 9TH AVE, DENVER, CO |
| Air Conditioning Service and Repair 2 ac inspections customer | S PONTIACT, DENVER, CO |
| Air Conditioning Service and Repair A/c checks two units upper unit has completely lost its charge and condenser needs to be cleaned lower unit condenser needs to be cleaned and unit is under charged | NEWTON ST, DENVER, CO |
| Air Conditioning Service and Repair Estimate wall unit not cooling gave estimate for replacement 800sf apartment top floor 12k btu wall unit | EMERSON, DENVER, CO |
| Air Conditioning Service and Repair A/c check will be calling to schedule cleaning possible dirty evap coil | E GIRARD, DENVER, CO |
| Air Conditioning Service and Repair A/c check. found unit working. recommend cleaning | SPRUCE ST, DENVER, CO |
| Air Conditioning Service and Repair Leak repair found system flat continued inside inspection | JOSEPHINE, DENVER, CO |
| Air Conditioning Service and Repair No a/c blower not running fuse blown on furnace replaced fuse blower not coming to speed over amp draw | SO. GILPAN, DENVER, CO |
| Air Conditioning Service and Repair A/c inspection found unit very dirty in need of pro tune and clean | W 69TH AVE, DENVER, CO |
| Air Conditioning Service and Repair A/c inspection found very dirty unit will need to be cleaned to further check system | E., DENVER, CO |
| Air Conditioning Service and Repair Installed capacitor indoor blower motor not working found burn spot on capacitor | HOLLY ST, DENVER, CO |
| Air Conditioning Service and Repair Cleaned condenser as per bid #42682 cleaned condenser and unit found erratic freon pressures possible non condensable in lines unit is working at this time did not clean furnace or evap coil | E., DENVER, CO |
| Air Conditioning Service and Repair Protune and clean outside unit is very dirty and it is recommended that it be cleaned indoor coil is lean however fan motor should be cleaned and coil sprayed with foam cleaner system super heat 8' pressures 70/265 s/a 51' r/a 74' st 23' | PEARL ST #, DENVER, CO |
| Air Conditioning Service and Repair Sprinkler installation, air conditioning diagnostic, repair - hvac | W. 32nd Ave. (check in), Denver, Co |
| Air Conditioning Service and Repair Estimate for new a/c unit. home currently does not have an air condition unit. | S. ACOMA ST, DENVER, CO |
| Air Conditioning Service and Repair A/c inspection - 1400 sq ft basement - 2 ton air condition unit, all but 1 adjoining units have 3 ton air condition units. equipment clean - charged fine - equip might be slightly under charged. the premium unit replacement qualifies for federal tax rebate, manuf rebate & xcel rebate. | E. 29TH AVE, DENVER, CO |
| Air Conditioning Service and Repair A/c not cooling - discovered capacitor on air condition unit was bad. after further diagnosis also determined compressor failed has a service partner plan. | CHERRY, DENVER, CO |
| Air Conditioning Service and Repair A/c no cooling. found breaker was shut off at disconnect. re-stored power and unit came on. thoroughly went through unit. recommendation & findings on service partner sheet attached. 8' super heat, 1/4? = 85' & s/a = 63'. protune and clean and service agreement | SO. ELIOT ST, DENVER, CO |
| Air Conditioning Service and Repair Air conditioner unit was froze up after further inspection discovered unit was low on charge repair air condition unit | SO., DENVER, CO |
| Air Conditioning Service and Repair A/c not working found frozen up and outdoor unit is dirty. recommend complete clean and freaon adjustment. only cleaned outdoor coil no freon adjustment | STEELE ST, DENVER, CO |
| Air Conditioning Service and Repair A/c not cooling found unit low on 410a and removed 410a pressure tested system. king valve was leaking replaced both schrader valves vacuumed down system to 500 microns and recharged to proper level tested ok at this time | GRAPE ST, DENVER, CO |
| Air Conditioning Service and Repair Estimate a/c does not include electrical to disconnect at condenser from panel | E KENTUCKY, DENVER, CO |
| Air Conditioning Service and Repair Air conditioner not working. found ssu fuse was blown replaced fuse and restored power to unit discovered idbm was operating @ low speed and high amps 12 amps normal + 8.5 determined motor was failing and needs to be replaced | E 5TH AVE, DENVER, CO |
| Air Conditioning Service and Repair Estimate a/c does not include electrical to disconnect at condenser from panel | E KENTUCKY, DENVER, CO |
| Air Conditioning Service and Repair Air conditioner not working. found ssu fuse was blown replaced fuse and restored power to unit discovered idbm was operating @ low speed and high amps 12 amps normal + 8.5 determined motor was failing and needs to be replaced | E 5TH AVE, DENVER, CO |
| Air Conditioning Service and Repair Air condition unit not working. found suction psig 100 lbs suction temp 68.5 coil american standard liquid psig 335lbs liquid temp 78' evap coil m# rxco31shpco s# 6211w895g condenser m# 4a7a4024b100aa s# 6094ld11f furnace weather king m# 80pj7ebr01 s# ge50302f14000945 | GRAPE ST, DENVER, CO |
| Air Conditioning Service and Repair Estimate for swamp cooler | STEELE ST, DENVER, CO |
| Air Conditioning Service and Repair Free estimate on plumbing repair, estimate - hvac | S Broadway, Denver, CO |
| Air Conditioning Service and Repair Serviced air conditioning, maintenance drain | S. Pennsylvania St., Denver, CO |
| Air Conditioning Service and Repair Replaced customer air conditioning unit, repair - hvac | S Broadway, Denver, CO |
| Air Conditioning Service and Repair Air condition unit not working. protune and clean mechanical inspection of hot water heating system and cooling system | E. KENYON, DENVER, CO |
| Air Conditioning Service and Repair A/c estimate unable to observe unit while running as customer had to leave this cooler should be replaced | MONROE ST, DENVER, CO |
| Air Conditioning Service and Repair Air conditioner not working. found bad capacitor. relaced capacitor and air condition unit working at this time | E 5TH AVE, DENVER, CO |
| Air Conditioning Service and Repair A/c not working found air condition unit dirty with low charge did protune and clean with top off | ULSTER ST, DENVER, CO |
| Air Conditioning Service and Repair A/c no cool checked evaporator coil clean checked condenser low charge 13.5 comp 5.5 .66 fan .2 r-22 orfice adjusted refrigerant on air conditioner | S HIGH ST, DENVER, CO |
| Air Conditioning Service and Repair Needs a protune & clean, did not want to do it. a/c has not been serviced in 6 years also needs fins combed | E, DENVER, CO |
| Air Conditioning Service and Repair Evaporative cooler not working water not pumping to pads found bad pump will give cost to repair installed new pump and unit is working at this time | S WILLIAMS, DENVER, CO |
| Air Conditioning Service and Repair Cleaned evaporator coil a/c freezing up will need to be cleaned . cleaned evaporator coil found it completely plugged system appears to be working at this time | JULIAN ST, DENVER, CO |
| Air Conditioning Service and Repair A/c inspection and estimate will have to do additional research | W 36TH PL, DENVER, CO |
| Air Conditioning Service and Repair Serviced air conditioning system and fixed leak, estimate - hvac | S Broadway, Denver, CO |
| Air Conditioning Service and Repair Serviced air conditioning system and fixed leak, repair - hvac | S Broadway, Denver, CO |
| Air Conditioning Service and Repair Swamp cooler shut down. need to drain down and install sheet metal pannels. shut down cooler and drainded line. installed winter pannels. will return before summer and hook everything back up. | E HARVARD, DENVER, CO |
| Air Conditioning Service and Repair Shut down swamp cooler found flue vent and elvow rusted in half. all co coming into basement | RUTH WAY, DENVER, CO |
| Air Conditioning Service and Repair Drain down swamp cooler for winter remove water line. winterize swamp cooler | MONROE ST, DENVER, CO |
| Air Conditioning Service and Repair Protune and clean on a/c unit uncased coil ac froze up frozen so badly that 5'x12x12 ice cube on outside of furnace filter plugged solid condenser 1/2 plugged uncased coil dogs in house filter fits poorly cut open a coil access and blocked half airflow to thaw preform protune and clean r-22 txv rawb 62 ra70 target at 17' at 19' 200/70 oat 72' 5 sh 16'sc sa 51' | S CORONA, DENVER, CO |
| Air Conditioning Service and Repair Replace blower motor in attic chiller unit. | WASHINGTON, DENVER, CO |
| Air Conditioning Service and Repair Returned to show customer how to change options on a/c unit and collect a/c payment and drop off new payment contract. | YATES ST, DENVER, CO |
| Air Conditioning Service and Repair Add ra greill to cover swamp cooler openening | S PATTON, DENVER, CO |
| Air Conditioning Service and Repair Air conditioning repair, maintenance - hvac | Poplar St, Denver, CO |
| Air Conditioning Service and Repair Air conditioning, maintenance - hvac | Clay St., Denver, CO |
| Air Conditioning Service and Repair Air condition repair and air condition tune up in dnever, repair - hvac | Logan, Denver, CO |
| Air Conditioning Service and Repair Air condition repair, repair - hvac | Logan, Denver, CO |
| Air Conditioning Service and Repair Air condition repair, repair - hvac | Logan, Denver, CO |
| Air Conditioning Service and Repair Furnace inspection , changed out filter, maintenance - hvac | E Mississippi Ave Building G 16, Denver, CO |
| Air Conditioning Service and Repair Furnace inspection , changed out filter, maintenance - hvac | E Mississippi Ave Building G 16, Denver, CO |
| Air Conditioning Service and Repair Replaced 10'' silcock for sprinkler system, maintenance - hvac | Liverpool St, Denver, CO |
| Air Conditioning Service and Repair Replaced 10'' silcock for sprinkler system, maintenance - hvac | Liverpool St, Denver, CO |
| Air Conditioning Service and Repair Replaced 10'' silcock for sprinkler system, maintenance - hvac | Liverpool St, Denver, CO |
| Air Conditioning Service and Repair Replaced 10'' silcock for sprinkler system, maintenance - hvac | Liverpool St, Denver, CO |
| Air Conditioning Service and Repair Replaced 10'' silcock for sprinkler system, maintenance - hvac | Liverpool St, Denver, CO |
| Air Conditioning Service and Repair Air conditioner tune up, maintenance - hvac | S Ivan Way, Denver, CO |
| Air Conditioning Service and Repair Condenser install,furnace upgrade,rebate,install a/c,refrigerant,cold air,venting,furnace start up,furnace cleaning carbon monoxide check, maintenance - hvac | Olive St., Denver, |
| Air Conditioning Service and Repair Condenser install,furnace upgrade,rebate,install a/c,refrigerant,cold air,venting,furnace start up,furnace cleaning carbon monoxide check, maintenance - hvac | Olive St., Denver, |
| Air Conditioning Service and Repair Condenser install,furnace upgrade,rebate,install a/c,refrigerant,cold air,venting,furnace start up,furnace cleaning carbon monoxide check, maintenance - hvac | Olive St., Denver, |
| Air Conditioning Service and Repair 2011 january pm contract | E, DENVER, CO |
| Air Conditioning Service and Repair 2011 january pm contract | E, DENVER, CO |
| Air Conditioning Service and Repair 2011 january pm contract | E, DENVER, CO |